Articles and technical guides

What actually shortens a cable's life

A cable designed for thirty years can fail in five. In the large majority of cases the cause was not a manufacturing defect.

2025-07-15All articles

Temperature governs everything

A rule of thumb the industry accepts: every 8 to 10 °C above the design operating temperature halves the expected life of the insulation. An XLPE cable rated 90 °C running continuously at 100 °C does not lose some of its life. It loses half.

Which is why loading and grouping errors that look marginal on paper are really errors in lifetime rather than performance: the cable works, works correctly, and dies early.

Water in a cable not built for it

Water treeing: under electrical stress, moisture migrates into the insulation and forms microscopic branches that grow for years until the insulation breaks down. It is the leading cause of failure in buried distribution cable.

The remedy is a design decision, not an operating one: a longitudinal and radial water barrier, or a lead sheath where the ground is saturated. Specifying that at purchase is far cheaper than discovering it later.

The damage is done during installation

Half of all shortened life is created in the week of pulling: tension beyond the permitted limit, a bending radius tighter than allowed, a pull over a sharp edge, a drum left open so moisture entered through an unsealed end.

A sharp bend does not cut the insulation; it thins it locally, so the electrical stress rises at exactly that point. The cable is tested, passes, and fails years later in the same place.

Joints and terminations

Most medium-voltage faults occur at a joint or a termination rather than along the cable. Making a joint is a matter of cleanliness, dimensional accuracy and a trained crew — and it is the item most often compressed when the programme slips.

What to do about it

Size with realistic correction factors rather than ideal ones; specify a water barrier if the run is buried; require a batch test report; and either train the jointing crew or buy the service with the product.

Originally published on zmscable.fr